   Hotomatic Gas Water Heater Specifications                          

Model

Specifications

 View

 

Models

2STDN

Natural Gas


2STDLP

LP Gas


 3STDN

Natural Gas


3STDLP

LP Gas

 

 

 

 

 

 

 

 

 

HotMatic® Gas Water Heater

We have 2 models of gas water heaters.  

Both run on LP gas or Natural Gas

Prices do not include shipping.  Shipping runs from $65-95 per unit.

Materials Specification Sheet

 

Types Hotomatic®
No. 2 STD
Hotomatic®
No. 3 STD
Gallons Per Hr. Recovery 90 (60°R)
45 (120°R)
150 (60°R)
75 (120°R)
Gallons Per Minute 1.5 (60°R)
.75 (120°R)
2.5 (60°R)
1.25 (120°R)
BTU Input (Approx.) 65,000 120,000
Vent size 4 inches 4 inches
Height (Not Including diverter) 221/2 inches 30 inches
Square 111/4 inches 13 3/4inches
Weight (Crated) 47 lbs. 79 lbs.
Gas Line Size
Up To 15' Long
1/2 inch I.D. 1/2 inch I.D.
Water Connections
(Standard Pipe Size)
3/4" F   3/4" F
Heater  Prices $1075.00 $1250.00
Replacement Coil List Prices $525.00
18 G
$625.00
18 G

Spark Igniter, Model V-1
List Price - $43.00

Relief Valve, Model #7413 - 600 psi
List Price - $70.00

Relief Valve, Model #7422 - 1000 psi
List Price - $70.00

Gas Pressure Regulator, Model #204-00
140,000 BTU/Hr for No. 1, No. 2, No. 3 Hotomatic® Heater
List Price - $43.00

Gas Pressure Regulator, Model # LV4403C9
575,000 BTU/Hr for No. 4 Hotomatic® Heater
List Price - $95.00

Special POL Plug
List Price - $12.00

 Important Note: It is extremely necessary that the Gas Pressure Regulator used to supply the heater with LP Gas has a capacity rating higher than the consumption of the heater. Too small a regulator will decrease the gas flow, the gas pressure and the amount of hot water produced. The Model #204­00 Regulator is rated at 140,000 BTU/Hr., which is sufficiently sized to supply the gas for Models  #2 or #3 Hotomatic® heaters.

Materials Specification Sheet

 

 

A gas supply hose that is too small will reduce the flow rate of the LP Gas. This reduces the gas pressure at the burner and the amount of hot water produced. Use a 1/2" I.D. Hose minimum for the #1, #2 or #3 HT Hotomatic heaters. Use a 3/4" I.D. Hose for the #4 HT Hotomatic heater.

 

 

 

 

Experience the Difference